- Use all specified fasteners: (8) 16d nails for header and (6) 16d nails for joist
- Not for use with treated lumber
- Joist nails must be driven in at 30-45° angle through joist or truss into header to achieve listed loads; standard length "double shear" nails must be used to achieve listed load values
- 16d sinkers (9 gauge x 3-1/4") may be used where 10d commons specified with no load reduction